04 · Department
Corrosion testing of metals, alloys and coatings
The corrosion department of Divine Metallurgical Services Private Limited, in Odhav, Ahmedabad, tests how metals and coatings resist attack in their service environment.
On this page, each test keeps its standard number, so you can match it to your specification.

Test groups
All 32 corrosion tests, by the attack they reproduce
Open a group to see every test in it, with its standard and what it proves.
Intergranular corrosion (IGC)
16 testsWelding or the wrong heat treatment can sensitise stainless steels and nickel alloys, so their grain boundaries corrode first. IGC tests find this before the material goes into process plant service.
- Used for
- Austenitic, ferritic and duplex stainless steels and nickel-chromium alloys
Tests
- IGC Practice A (ASTM A262, austenitic SS)
The oxalic acid etch test, a rapid screening test for austenitic stainless steel such as 304 and 316. It shows whether the material is free of sensitisation or needs one of the longer IGC tests.
- IGC Practice B (ASTM A262, austenitic SS)
The Streicher test, in ferric sulphate and sulphuric acid. It measures the intergranular corrosion rate of austenitic stainless steel and detects sensitisation from chromium carbide precipitation.
- IGC Practice C (ASTM A262, austenitic SS)
The Huey test, in nitric acid. It measures the intergranular corrosion rate of austenitic stainless steel, and is ordered for plant in nitric acid and other oxidising service.
- IGC Practice E (ASTM A262, austenitic SS)
The Strauss test, in copper sulphate and sulphuric acid. It is widely specified to prove that austenitic stainless steel plate, pipe, fittings, forgings and welds are free of sensitisation.
- IGC Practice F (ASTM A262, austenitic SS)
A copper sulphate and sulphuric acid test for intergranular attack in molybdenum-bearing austenitic stainless steel, including cast grades such as CF3M and CF8M.
- IGC Practice W (ASTM A763, ferritic SS)
The oxalic acid etch test for ferritic stainless steel. A rapid screening test that shows whether one of the longer intergranular corrosion tests is needed.
- IGC Practice X (ASTM A763, ferritic SS)
The ferric sulphate and sulphuric acid test. It measures the intergranular corrosion rate of ferritic stainless steel sheet, plate, tube and welds.
- IGC Practice Y (ASTM A763, ferritic SS)
A copper sulphate and sulphuric acid test that detects intergranular attack in ferritic stainless steel, used for high-chromium grades such as 446.
- IGC Practice Z (ASTM A763, ferritic SS)
A copper sulphate and sulphuric acid test that detects intergranular attack in ferritic stainless steel, used for grades such as 430, 439 and 444.
- IGC Huey test (ISO 3651-1, duplex SS)
The Huey test in nitric acid, to the ISO standard. It measures how well duplex and austenitic stainless steel resist intergranular corrosion in strongly oxidising service.
- IGC Practice A (ISO 3651-2, ferritic, austenitic and duplex SS)
The ISO copper sulphate and sulphuric acid test, also known as the Monypenny Strauss test. It detects sensitisation in ferritic, austenitic and duplex stainless steel.
- IGC Practice B (ISO 3651-2, ferritic, austenitic and duplex SS)
A copper sulphate and sulphuric acid test to the ISO standard, used for stainless steel grades with higher chromium and molybdenum content.
- IGC Practice C (ISO 3651-2, ferritic, austenitic and duplex SS)
The ISO ferric sulphate and sulphuric acid test, used for highly alloyed austenitic, ferritic and duplex stainless steel.
- IGC Method A (ASTM G28, Ni-Cr alloys)
The ferric sulphate and sulphuric acid test for wrought nickel-rich, chromium-bearing alloys. It detects susceptibility to intergranular corrosion in alloys such as 625, 825 and C-276.
- IGC Method B (ASTM G28, Ni-Cr alloys)
The mixed acid and oxidising salt test for nickel-chromium-molybdenum alloys such as C-276 and C-22. It detects susceptibility to intergranular corrosion after welding or heat treatment.
- Weld decay test
Checks the weld and heat-affected zone of welded stainless steel tube and pipe for preferential corrosion, the attack known as weld decay.
Pitting, crevice and chloride cracking
4 testsChlorides in seawater and process fluids cause pitting, crevice attack and stress corrosion cracking. These tests rank stainless steels and nickel alloys before they are chosen for such service.
- Used for
- Stainless steels and nickel alloys for chloride service
Tests
- Pitting & crevice corrosion test Method A (ASTM G48)
The ferric chloride pitting test. It shows the resistance of stainless steel and nickel alloys to pitting corrosion in chloride service, and is widely specified for duplex and super duplex welds.
- Pitting & crevice corrosion test Method B (ASTM G48)
The ferric chloride crevice corrosion test. It shows how stainless steel and related alloys resist attack inside crevices, as found under gaskets, washers and deposits.
- Pitting & crevice corrosion test Method C (ASTM G48)
The critical pitting temperature (CPT) test for nickel-base and chromium-bearing alloys. It finds the lowest temperature at which pitting starts, so alloys can be ranked.
- Chloride stress corrosion cracking (ASTM G36)
The boiling magnesium chloride test. It shows whether wrought, cast or welded stainless steel and related alloys are prone to chloride stress corrosion cracking (SCC).
Intermetallic phases in duplex stainless steel
3 testsSigma and other intermetallic phases can form in duplex stainless steel during processing and reduce its toughness and corrosion resistance. These tests confirm the material is free of them.
- Used for
- Duplex and super duplex stainless steel products and welds
Tests
- Intermetallic phase test Method A (ASTM A923, duplex SS)
The sodium hydroxide etch test, a rapid screening test. It shows whether duplex stainless steel is free of detrimental intermetallic phases such as sigma phase.
- Intermetallic phase test Method B (ASTM A923, duplex SS)
A Charpy impact test that shows whether intermetallic phases have reduced the toughness of duplex stainless steel plate, pipe, fittings and welds.
- Intermetallic phase test Method C (ASTM A923, duplex SS)
The ferric chloride corrosion test. It shows whether intermetallic phases have reduced the corrosion resistance of duplex and super duplex stainless steel.
Sour service and hydrogen damage
4 testsSteels for oil and gas service with hydrogen sulphide are tested for sulphide stress cracking and hydrogen-induced cracking. Sulphide stress cracking is tested on proof rings, or by four-point bend loading set with strain gauges. The diffusible hydrogen test measures hydrogen in weld metal, a cause of cold cracking.
- Used for
- Line pipe, pressure vessel steels, oil and gas equipment and welding consumables
Tests
- Sulphide stress corrosion cracking (SSC Method A, NACE TM0177)
The NACE tensile test for sulphide stress cracking (SSC), run on proof rings. It is used to qualify carbon steel, low-alloy steel and corrosion-resistant alloys for sour (H2S) oil and gas service under NACE MR0175 / ISO 15156.
- Sulphide stress corrosion cracking (4-point bend with strain gauge, NACE TM0316)
The four-point bend test for sulphide stress cracking (SSC) in sour service, with the specimen load set by a strain gauge setup. Ordered for line pipe, plate and welded joints.
- Hydrogen induced cracking (HIC, NACE TM0284)
Shows whether line pipe and pressure vessel steel resists hydrogen-induced cracking (HIC), also called stepwise cracking, in wet H2S service. The report gives the crack ratios CLR, CTR and CSR.
- Diffusible hydrogen test (AWS A4.3)
Measures the diffusible hydrogen in weld metal from electrodes, filler wires and fluxes. It confirms the low-hydrogen class of a welding consumable, since hydrogen causes cold cracking.
Copper alloy tests
4 testsBrass and other copper alloys are tested for dezincification in water service, and for the residual stress that leads to ammonia or season cracking.
- Used for
- Brass and copper alloy fittings, tubes and components
Tests
- Dezincification test
Shows whether brass loses zinc in water service and turns weak and porous. Ordered for brass valves, taps, fittings and plumbing parts, including dezincification-resistant (DZR) brass.
- Ammonia stress corrosion cracking (ASTM B858, ISO 6957)
The ammonia vapour test. It detects residual stress in brass and copper alloy tubes, rods and fittings that can lead to stress corrosion cracking in service.
- Season crack test
Checks brass and other copper alloy parts for the residual stress, left by drawing or forming, that causes season cracking in storage or service.
- Mercurous nitrate test
A residual stress test for copper alloys. It shows whether brass tubes, rods and formed parts carry internal stress high enough to cause cracking.
Salt spray test
1 testA salt fog cabinet compares the corrosion protection given by paints, platings and other coatings. It is used for quality control and for comparing coating systems.
- Used for
- Painted, powder-coated, plated and galvanised parts
Tests
- Salt spray test
The salt fog test, also called neutral salt spray (NSS). It compares the corrosion protection of paint, powder coating, plating and galvanising on finished parts and test panels.
Instruments
Instruments in the corrosion department
- Salt spray chamber
- Four SSC proof rings
- Four-point bend fixture with strain gauge setup
- HIC test chamber
Departments
Other departments and services
Enquiry
Send an enquiry to the laboratory
Tell the laboratory what you need tested.